| 31 | 0.75 mm² | Combination Switch (high beam switch) 10 | Flasher 31 |
| 56 | 0.75 mm² | Combination Switch (high beam switch) 56 | C202 3 |
| 56 | 0.5 mm² | C202 3 | C103 3 |
| 56 | 0.5 mm² | C103 3 | Fog Light Switch 4 |
| 56 | 0.5 mm² | Fog Light Switch 4 | Light Switch 3 |
| 56a | 0.75 mm² | C202 4 | Combination Switch (high beam switch) 8 |
| Battery bus | 0.75 mm² | Power distribution (hot at all times, C100) 1 | K3 High Beam Relay 30 |
| Battery bus | 0.75 mm² | Power distribution (hot at all times, C100) 1 | K8 Fog Light Relay 30 |
| Cluster ground | 0.5 mm² | Instrument Cluster printed circuit C2-16 | G200 GND |
| Fog feed | 0.75 mm² | K8 Fog Light Relay 87 | Power Distribution Box fuses 30/29 87 |
| Fog indicator | 0.5 mm² | Power Distribution Box fuses 30/29 29 | Instrument Cluster printed circuit C2-22 |
| Fog relay 86 | 0.5 mm² | K8 Fog Light Relay 86 | C103 12 |
| Fog relay coil feed | 0.75 mm² | K4 Low Beam Relay 87 | K8 Fog Light Relay 85 |
| Fog switch | 0.5 mm² | C103 12 | Fog Light Switch 2 |
| Ground | 0.75 mm² | Flasher 31 | G201 (steering column ground) GND |
| Ground | 0.75 mm² | Flasher 31 | C202 8 |
| Ground | 0.75 mm² | C202 8 | G200 GND |
| Ground | 0.5 mm² | Light Switch 8 | S306 T |
| Ground | 1.5 mm² | S306 B | C103 9 |
| Ground | 1.5 mm² | C103 9 | G200 GND |
| Ground | 2.5 mm² | S114 R | S100 L |
| Ground | 4.0 mm² | S100 B | G104 GND |
| Ground distribution | 0.75 mm² | Ground distribution 1 | S306 L |
| Ground distribution | 0.75 mm² | Ground distribution 1 | S114 R |
| Ground distribution | 1.0 mm² | Ground distribution 2 | S100 L |
| High beam | 0.75 mm² | K3 High Beam Relay 87 | H: to fuses 1 and 2 H |
| High beam control | 0.5 mm² | K3 High Beam Relay 85 | C202 4 |
| K3 87a to K4 30 | 1.0 mm² | K3 High Beam Relay 87a | K4 Low Beam Relay 30 |
| LH fog | 1.0 mm² | Power Distribution Box fuses 30/29 29 | C126 1 |
| LH fog | 0.75 mm² | C126 1 | LH Fog Light 1 |
| LH fog ground | 0.75 mm² | LH Fog Light 2 | C126 2 |
| LH fog ground | 1.0 mm² | C126 2 | S100 T |
| Low beam | 0.75 mm² | K4 Low Beam Relay 87 | L: to fuses 13 and 14 L |
| Low beam relay 85 | 0.5 mm² | K4 Low Beam Relay 85 | C103 3 |
| RH fog | 1.0 mm² | Power Distribution Box fuses 30/29 30 | C127 1 |
| RH fog | 0.75 mm² | C127 1 | RH Fog Light 1 |
| RH fog ground | 0.75 mm² | RH Fog Light 2 | C127 2 |
| RH fog ground | 1.0 mm² | C127 2 | S114 T |
| Run bus | 0.75 mm² | Power distribution (hot in run or start) 1 | K3 High Beam Relay 86 |
| Run bus | 0.75 mm² | Power distribution (hot in run or start) 1 | K4 Low Beam Relay 86 |