| B+ to PDB | 10 mm² | Battery + | Power Distribution Box C100 |
| Backup lights | 2.5 mm² | Automatic Transmission Range Switch 1 | Backup Lights 1 |
| Battery ground | 0.75 mm² | Battery - | G100 GND |
| Battery to starter | 16 mm² | Battery + | Starter 30 |
| Charging system | 10 mm² | Starter 30 | Charging System 1 |
| Cruise control | 0.5 mm² | Start Relay 86 | Cruise Control 1 |
| Diag 11 | 2.5 mm² | S107 B | Diagnostic Connector 11 |
| Fuse 10 to K7 coil | 0.75 mm² | Power Distribution Box Fuse 10 7.5A 10 | K7 Unloader Relay 86 |
| Fuse details | 0.75 mm² | S212 R | Fuse Details 1 |
| Ign 15 | 2.5 mm² | Ignition Switch 15 | C200 2 |
| Ign 15 | 2.5 mm² | C200 2 | S213 R |
| Ign 15 to PDB | 2.5 mm² | S213 L | Power Distribution Box C114-4 |
| Ign 30 | 4.0 mm² | S232 R | C200 9 |
| Ign 30 | 4.0 mm² | C200 9 | Ignition Switch 30 |
| Ign 50 | 2.5 mm² | Ignition Switch 50 | C200 10 |
| Ign 50 | 2.5 mm² | C200 10 | Start Relay 30 |
| Instrument cluster | 0.5 mm² | S233 R | To Instrument Cluster (link S) S |
| Internal bus to K5 86 | 0.75 mm² | Power Distribution Box C114-4 | K5 Unloader Relay 86 |
| Internal bus to K7 30 | 0.75 mm² | Power Distribution Box C114-4 | K7 Unloader Relay 30 |
| Internal power distribution | 0.75 mm² | Power Distribution Box C114-4 | Power distribution (inside PDB) 1 |
| Park/neutral to DME | 0.75 mm² | Automatic Transmission Range Switch 9 | C132 1 |
| Park/neutral to DME | 0.75 mm² | C132 1 | C131 1 |
| Park/neutral to DME | 0.5 mm² | C131 1 | Motronic Control Unit 42 |
| Power distribution | 0.75 mm² | S232 B | Power Distribution 1 |
| Power distribution | 0.75 mm² | S213 B | Power Distribution 1 |
| Power distribution to K5 30 | 0.75 mm² | Power distribution (inside PDB) 1 | K5 Unloader Relay 30 |
| Range switch feed | 0.75 mm² | S212 B | C301 1 |
| Range switch feed | 0.75 mm² | C301 1 | Automatic Transmission Range Switch 3 |
| S212 | 0.75 mm² | Power Distribution Box Fuse 10 7.5A 10 | S212 T |
| S232 | 4.0 mm² | Power Distribution Box C100-OUT | S232 L |
| SRS (not used) | 0.5 mm² | S233 L | C240 SRS Connector (not used) 5 |
| Start | 2.5 mm² | Start Relay 87 | C241 1 |
| Start | 2.5 mm² | C241 1 | S233 R |
| Start | 2.5 mm² | S233 B | C101 18 |
| Start | 2.5 mm² | C101 18 | S107 T |
| Start relay coil | 0.75 mm² | Automatic Transmission Range Switch 9 | Start Relay 86 |
| Start relay ground | 0.75 mm² | Start Relay 85 | G200 GND |
| Starter 50 | 2.5 mm² | S107 L | Starter 50 |
| Starter case ground | 0.75 mm² | Starter GND | Starter case ground GND |
| Unloader relay coils | 0.5 mm² | K7 Unloader Relay 85 | S233 L |
| Unloader relay coils | 0.5 mm² | K5 Unloader Relay 85 | S233 L |